Mercury filter change indicator is reliable and cost effect means for protection from exposure to toxic mercury & mercury II compounds vapors

Mercury & Mercury II Compounds Vapors Filter Breakthrough Indicator

Mercury Indicator • Mercury II Compounds Indicator • Filters Change Indicator

Item No. 184

Product Features
Minimum detectable limit: 0.3mg/m3•hr
Color Change: Off white to peach
Inlet dimensions: ¾” Male NPT
Service life: 14 months

$76.44

Mercury filter change indicator. It is a colorimetric indicator that indicates the exhaustion of filters. The indicator is reliable and cost effect means for protection from exposure to toxic mercury & mercury II compounds vapors. It changes color from off white to peach when filter is saturated with mercury & mercury II compounds vapors. Hence alerting the user to replace the exhausted filter.

Connects easily to the ¾ inch female NPT outlet of the filter using the ¾ inch male NPT threading at the bottom of the indicator. Bright vibrant color change from all directions. Unique design prevents any color change due to exposure to contaminants in the surrounding environment. It changes color only when filter is saturated.

PN 184

Product Specifications

a

Weight:28g (1.0oz)

b

Dimensions:89.9mm (3.5in), diameter 24.5mm (1.0in)

c

Inlet dimensions:¾” MNPT

d

Operating temperature:-20oC to 55oC (-4oF to 131oF)

e

Operating humidity:

5% RH to 85%RH

f

Minimum detectable limit:0.3mg/m3•hr at 30 cm/sec face velocity

g

Color change:Off white to peach

h

Storage temperature:4oC to 25oC, (39oF to 77oF)

i

Shelf life:12 months at 4oC to 25oC, (39oF to 77oF)

j

Service life:12 months