Acids Breakthrough-Indicator Sticker B

Acids Breakthrough Indicator Sticker Type B (BTIS B)

Acids leak detector for chemicals transport vehicles

Item No. 250

Dimensions: Diameter = 38.1mm (1.5in), Height = 2.0mm (0.11in), SOLD IN PACKS OF 5

(Pack of 5)

$101.50

Acids Breakthrough-Indicator Sticker B (BTIS B) – PN 250. Is a leak detector for use in chemicals transport vehicles and chemical storage cabinets. Suitable locations are the inside of glass window of chemical transport vehicle, or the inside glass window of chemical storage cabinet where representative samples can be obtained. Reliable and cost effective. Operates under extreme conditions and has extended service life.

How to use the BTIS B?

  1. Remove adhesive protective liner from the front of sticker.
  2. Attach to center clean area of the inside glass window of chemicals transport vehicle or chemical storage cabinet with the reading area (glossy surface) of the sticker facing inside glass window.
  3. Color change indicates leak.

Product Specifications

aWeight:0.4g (0.02oz)
bDimensions:2.8mm (0.11in), diameter: 38.1mm (1.5in)
cOperating temperature:0oC to 55oC (32oF to 122oF)
dOperating humidity:5% RH to 90%RH
eMinimum detectable limit:1ppm•min. at 30 cm/sec face velocity
fColor change:orange to red
gStorage temperature:4oC to 25oC, (39oF to 77oF)
hShelf life:1 year at 4oC to 25oC, (39oF to 77oF)
iService life:60 days

Acids Breakthrough-Indicator Sticker B

Useful Links
NIOSH
Filter Change Indicators

Facts about hydrogen chloride

Hydrogen chloride (HCl) is a colorless to slightly yellow gas with a pungent odor. Hydrogen chloride can irritate the skin, nose, eyes, throat, and larynx. Exposure to liquid hydrogen chloride may cause frostbite. Workers may be harmed from exposure to hydrogen chloride. The level of harm depends upon the dose, duration, and work being done.