Luft - und Raumfahrt
Home / Anwendungen / Luft - und Raumfahrt

Aerospace emission control devices
Chemteq manufactures area monitors as well as filter change indicators and filters with end-of-service life indicators. Applications include hydrazines, MIL-87930, H-70 und nitrogen dioxide.
Filter Change Indicators
These filter change indicators, suitable for drum-type filters are; BTI , BTI Inline, BTI with auxiliary filter trap (suitable for highly toxic substances such as hydrazines). BTI 2 und BTI 3.
Filter Change Indicator Stickers
Die BTIS are filter change indicators stickers for ductless hood filters, the BTIS B are leak detectors suitable for chemical cabinets and chemical transport vehicles .
We also manufacture three different sizes of filters with end-of-service life indicators for hydrazines, MIL-87930, H-70 and nitrogen dioxide.
Custom cut colorimetric indicators are available for wide range of chemicals including hydrazines, MIL-87930, H-70 and nitrogen dioxide.
Our indicators have shelf-life range between one year and two years, plus service life range between one year and two years. Sun light has no effect on the hydrazine indicators and they are waterproof.
Produkteigenschaften:
| ||
a | Durchmesser und Gewinde | BTI: 1”. Inlet threading 0.75” MNPT BTI-Inline: 1”. Inlet & 0utlet threading 0.75” MNPT BTI AFT*: 1” BTI2: 2”. Inlet threading 1.5” MNPT BTI3: 3”. Inlet threading 2.5” MNPT |
b | Höhe | BTI: 3.5” BTI-Inline: 3.5” BTI AFT*: 5.1” BTI2: 4.5” BTI3: 4.5” |
c | Betriebstemperaturbereich: | -20 – 4oC to 50 – 65oC (-4 – 39oF to 122 -149oF). |
d | Betriebsfeuchtigkeit: | 5% RH to 95%RH |
f | Haltbarkeitsbereich: | 1-2 years |
g | Lebensdauerbereich: | 1-2 years |
h | Zulässige Flüssigkeiten: | Gases and vapors |
* Filter change indicator with auxiliary filter trap
2. Aufkleber zur Filterwechselanzeige | ||
a | Durchmesser | Area Monitors**: 1.5” BTIS: 1.25” BTIS B***: 1.5” |
b | Dicke | Area Monitors: 0.12” BTIS: 0.12” BTIS B***: 0.12” |
c | Betriebstemperaturbereich: | -20 – 4oC to 50 – 65oC (-4 – 39oF to 122 -149oF). |
d | Betriebsfeuchtigkeit: | 5% RH to 95%RH |
f | Haltbarkeitsbereich: | 1-2 years |
g | Lebensdauerbereich: | 1-2 years |
h | Zulässige Flüssigkeiten: | Gases and vapors |
** Überwachung der Luftqualität. Geeignete Standorte, am Schornstein, Schacht, Entlüftung oder Schornstein
*** Leak detectors suitable for chemical cabinets and chemical transport vehicles
Nützliche Links
Aerospace emission control devices
-
(Pack of 5)
Basic Vapors Area Monitor
$168.00 -
Hydrazine DG FILTER-ESLI-2517
$723.50 -
Organic Vapors DG FILTER-761
$571.98 -
Nitrogen Dioxide DG FILTER-756
$531.98 -
Mercury DG FILTER-754
$571.98 -
Hydrazines DG FILTER-745
$571.98 -
(Pack of 5)
Hydrazines Breakthrough-Indicator Sticker Type B (BTIS B)
$126.23