Cart $0.00
0
0
Subtotal: $0.00

No products in the cart.

Allyl Bromide Indicator and Detector

Allyl Bromide Breakthrough Indicator with Auxiliary Filter Trap (BTI AFT)

Allyl Bromide Filter Change Indicator with Auxiliary Filter Trap.

Item No. 671

Product Features
Minimum detectable limit: 3.ppm•hr ammonia at 30 cm/sec face velocity
Color Change: Brown to dark brown
Dimensions: Part A: 89.9mm (3.5in), diameter 24.5mm (1.0in
Part B: 41mm (1.6in), diameter 81mm (3.2in)
Service life: 1 year

$105.84

Allyl Bromide Indicator (BTI AFT) is filter change indicator with auxiliary filter trap designed to provide real time indication of the breakthrough of allyl bromide. Indicator is equipped with auxiliary filter trap to ensure no gases or vapors escape to the outside environment while the indicator changing color.

How the BTI AFT works?

When filter is consumed, toxic gases and vapors breakthrough it. The contaminated air then enters the BTI AFT and chemically reacts with the indicating sensor. Producing vivid color change, alerting the user to change the filter.

How to use the BTI AFT?

  1. Remove bottom protective red plug from the bottom of the breakthrough indicator.
  2. Screw in the male NPT threading at the bottom of the indicator into same female threading at the outlet of your filter.
  3. Replace filter when the breakthrough indicator changes Color.

why is it essential to use filter change indicator & how to install it into your filter →
Learn more

PN 671

Product Specifications

aWeight:118g (4.2oz)
bDimensions:Part A: 89.9mm (3.5in), diameter 24.5mm (1.0in

Part B: 41mm (1.6in), diameter 81mm (3.2in)

cInlet dimensions:¾” MNPT
dOperating temperature:4oC to 32oC (39oF to 89.6oF)
eOperating humidity:5% RH to 85%RH
fMinimum detectable limit:3ppm.hr at 30 cm/sec face velocity
gColor change:Brown to dark brown
hStorage temperature:4oC to 25oC, (39oF to 77oF)
iShelf life:1 year at 4oC to 25oC, (39oF to 77oF)
jService life:1 year

Related Products
Allyl Bromide BTI. Drum type filter change indicator
Allyl Bromide BTIS. for ductless hood and fume extractor filters.

Useful Link
NIOSH

Allyl Bromide Breakthrough Indicator (BTI AFT)